The Technology Behind The DESIRE
Great clinical results begin with the LightSheer DESIRE 805 nm diode laser empowered by two advanced technologies
- Vacuum Assisted High-Speed Integrated Technology A large 22×35 mm spot size enables the use of low-fluence and with a unique mechanism for pain reduction provides effective, fast and comfortable treatment.
- ChillTip™ Technology – Integrated contact cooling provides epidermal protection for treatment areas requiring precision and higher fluence.
![handpiece4](https://lumenis.com/wp-content/uploads/2018/07/handpiece4.png)
3 Handpieces For Treating All Body Areas
![hp1_1](https://lumenis.com/wp-content/uploads/2018/07/hp1_1.png)
The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing, fast and comfortable treatment.
![hp2_1](https://lumenis.com/wp-content/uploads/2018/07/hp2_1.png)
The XC has a Sapphire ChillTip spot size of 12x12mm, providing a solution for large and small areas requiring higher fluence levels
![hp3_1](https://lumenis.com/wp-content/uploads/2018/07/hp3_1.png)
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and higher fluence.
Cutting Edge Technologies
![interface](https://lumenis.com/wp-content/uploads/2018/07/interface.png)
Advanced Graphical User Interface
Intuitive presets for fast learning curve and easy treatment delegation.
- Hair removal, permanent hair reduction, and the treatment for Pseudo Folliculitis Barbae (PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Platform | LightSheer DESIRE | ||
---|---|---|---|
HandPiece | HS | XC | ET |
Technical Specifications: | |||
Laser Type | AIGaAs Diode Arrays | AIGaAs Diode Arrays | AIGaAs Diode Arrays |
Wavelength | 805 nm (nominal) | 805 nm (nominal) | 805 nm (nominal) |
Spot Size | 22 mm X 35 mm | 12 mm X 15 mm | 9 mm X 9 mm |
Repetition Rate | Up to 3 Hz | Up to 3 Hz | Up to 3 Hz |
Pulse repetition | 1-3 Pulse | 1 Pulse | 1 Pulse |
Fluence | 4.5-12 J/cm2 | 10-40 J/cm2 | 10-100 J/cm2 |
Pulse Width(OptiPulse) | 30-400ms | 5-400 ms | 5-400 ms |
Peak Power | 2310 W | 1920 W | 1620 W |
Comfort Management | Vacuum assist (up to 18 in Hg) | Chilltip contact cooling (5°C) | |
Preset Parameters | Yes | Yes | |
Platform Specifications : | |||
Electrical | 100-240 VAC +/- 10% , 12 A max. | 50/60 Hz. | Single-phase grounded outlet | ||
Weight | 32 kg(70.5 lbs.) | ||
Dimensions (WxDxH) | 51 x 60 x 42 cm; (20.1 x 23.6 x 16.55 in) |
PB-00005640 Rev A